CRU DX115 DC Installation Guide

Browse online or download Installation Guide for HDD/SSD enclosures CRU DX115 DC. CRU DX115 DC User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Rugged, Reliable, Mobile, Secure
TM
1-800-260-9800 www.CRU-DataPort.com
NOTE: For SAS operation, a SAS controller and SAS hard drive are
required.
SAS DX115 DC receiving frame supports SAS and SATA drives. SATA
6Gb/s DX115 DC receiving frame supports SATA drives only.
Package Contents
(1) DX115 DC Receiving Frame and/or Drive Carrier
(4) M3 drive mounting screws for 2.5” drives
(4) #6-32 drive mounting screws for 3.5” drives
(4) M3 chassis mounting screws
(1) Power Adapter- Legacy 4pin to 15pin SATA
Carrier Handle
This handle allows the ejection and installation of the drive carrier.
To eject the carrier, simply push on carrier handle. Once handle pivots
outward, pull handle to remove carrier.
To install the carrier, simply insert the drive carrier into the receiving
frame. Push handle in to fully seat carrier into the receiving frame.
Power Button
The DX115 DC ships with the power button disabled. To enable the but-
ton remove the Power Button Disable jumper (see Figure 2 for details).
CAUTION: It is the responsibility of the user to ensure that the host
does not access the drive while attempting to remove the drive.
Failure to do so may result in loss of data and/or damage to the
drive itself!
* If the Power Button is enabled use the Power Button will function as
follows:
OFF - Press and hold down the power button until the Drive Ready LED
starts to flash. Drive is ready to be removed when the Drive Ready
LED is OFF.
ON* - Press and hold down the power button until the Drive Ready LED
starts to ash. Drive is ready to be accessed when the Drive Ready
LED is ON.
Operation
Drive Ready/Error LED
This bi-color LED indicates either the status of the drive or fan/DC
power, depending on the color.
Drive Ready (blue): Flashing blue LED indicates that drive is
inserted and powering up. Steady blue LED glow indicates drive is
powered on and ready for access.
Error (red): Flashing red and blue LED indicates a fan failure.
Steady red LED glow indicates DC power failure.
Drive Activity LED
This amber LED indicates when the host computer is accessing the data
on the drive. LED will flash during communication with the host computer.
Most SAS drives provide support for the Drive Activity LED feature (refer
to your SAS drive manufacturer’s documentation for further information).
If your drive does not support this feature, the Drive Activity LED can
be enabled via host connection (cable not included) to Pin 1 located on
Receiving Frame Motherboard (Figure 2). Refer to your SAS PC system/
host controller manufacturer’s documentation for further information.
Data Express DX115 DC SAS/SATA Install Guide
Removable SAS/SATA Drive Enclosure
Figure 1: Front Bezel
Carrier
Handle
Power
Button
Drive Ready/
Error LED
Drive
Activity
LED
Fan Error LED
Disable Button
Push Here to Eject Carrier
Page view 0
1 2

Summary of Contents

Page 1 - Operation

Rugged, Reliable, Mobile, SecureTM1-800-260-9800 www.CRU-DataPort.comNOTE: For SAS operation, a SAS controller and SAS hard drive are required.SAS DX1

Page 2 - Certification

Rugged, Reliable, Mobile, SecureTM1-800-260-9800 www.CRU-DataPort.comFan Error LED Disable Button This button allows the user to disable the Fan Error

Comments to this Manuals

No comments